- Home
- Sistemi
- Photovoltaic systems
- ISOTT VV
ISOTT VV
Sandwich panel consisting of a PIR foam insulation component without the use of CFCs or HCFCs compliant with the CAM Minimum Environmental Criteria, coated on both sides with a saturated mineral glass fibre coating. Due to its light weight and great rigidity, it is easy to move and position during installation.
APPLICATIONS: Insulation of walls, formwork and floors, roofing also under cold-applied synthetic or bituminous coverings. When laying, it is recommended that the panels be laid with staggered joints.
SIZE: 600 x1200; 1200 x 1200; 1200 x 2400 mm.
FINISH: Straight edges on all sides (shiplap edge available upon request for minimum production quantities)
THICKNESSES: 30-40-50-60-80-100-120-140-150-160-180-200mm.
(Panel available in other dimensions and thicknesses on request)
| Reaction to fire (EN 13501-1, EN 11925-2, EN 13823) | F |
| Compressive strenght at 10% crushing (EN 826) | 150 kPa |
| Compressive strenght at 2% crushing (EN 826) | >5000 kg/m2 |
| Tensile strenght perpendicular to faces | 40 kPa |
| Panel density (average value, including facing weights) – ρ | 45 ± 2 kg/m3 |
| Insulation density | 31 ± 2 kg/m3 |
| Specific heat Cp (average value) | 1458 J/kg °K |
| Vapour diffusion resistance factor (EN 12086) | μ= 33 ± 2 |
| Water absorption by partial immersion, short period (EN 1609) | < 0,3 kg/ m² |
| Dimensional stability (EN 1604) (level) | 3 per d < 60 mm 48 h, 70° C, 90% U 4 per d ≥ 60 mm |
| Tolerances [mm] (EN 13165) | Lunghezza e Larghezza: ± 5 < 1000 mm; ± 7,5 da 1001 a 2000 mm Spessore: ± 2 < 50 mm; ±3 da 50 a 75 mm; +5/-2 ≥ 75 mm |
Certificate
Trasmittance