ISOTT.L Alluminio centesimale
Sandwich panel consisting of a CFC- or HCFC-free expanded PIR foam insulation component compliant with the CAM Minimum Environmental Criteria, covered on both sides with an embossed aluminium coating. Due to its light weight and great rigidity, it is easy to move and position during installation.
APPLICATIONS: Thermal insulation in cavity, intermediate floor, radiant floor, flat and sloping roofs and bacacier systems.
SIZE: 600 x 1200; 1200 x 1200; 1200 x 2400 mm.
FINISH: Straight edges on all sides
THICKNESSES: 40-50-60-80-100-120-140-150-160-180-200 mm. (Panel can be supplied in other dimensions and thicknesses on request)
| Reaction to fire (EN 13501-1, EN 11925-2, EN 13823) | D-s1,d0 |
| Reaction to fire: Steel deck application, fire exposure from the interior (EN 13501-1, EN 11925-2, EN 13823) | B-s1,d0 |
| Reaction to fire “end use condition” – gypsum board application – exposed side (EN 13501-1, EN 11925-2, EN 13823) | B-s1,d0 |
| Reaction to fire: Roofing system (External Fire Exposure) (EN 13501-5, CENT/TS 1187) | Broof (t2, t3) |
| Compressive strenght at 10% crushing (EN 826) | 150 kPa |
| Tensile strenght perpendicular to faces | 40 kPa |
| Panel density (average value, including facing weights) – ρ | 40 ± 2 kg/m |
| Insulation density | 31 ± 2 kg/m3 |
| Specific heat Cp (average value) | 1370 J/kg °K |
| Vapour diffusion resistance factor (EN 12086) | μ= ∞ |
| Water absorption by partial immersion, short period (EN 1609) | < 0,1 kg/ m² |
| Dimensional stability (EN 1604) (level) | 3 per d < 60 mm 48 h, 70° C, 90% U 4 per d ≥ 60 mm 4 per d ≥ 60 mm 48 h, 70° C, 90% U |
| Tolerances [mm] (EN 13165) | Lunghezza e Larghezza: ± 5 < 1000 mm; ± 7,5 da 1001 a 2000 mm Spessore: ± 2 < 50 mm; ±3 da 50 a 75 mm; +5/-2 ≥ 75 mm |
| Compressive strenght at 2% crushing (EN 826) | >5000 kg/ m² |
| Emission of volatile organic compounds (UNI EN ISO 16000) | Classe Francese A+ – CAM Edilizia Italiana – LEED v4.1 BETA |
Certificate
Trasmittance
Static data