ISOTT Fire

Sandwich panel consisting of an insulating component made of expanded PIR foam without the use of CFCs or HCFCs in compliance with the CAM Minimum Environmental Criteria, covered on the side exposed to fire risk by a special fiberglass coating that expands in contact with flames, guaranteeing high fire protection, and on the other side by saturated mineral glass. Due to its light weight and great rigidity, it is easy to move and position during installation.

APPLICATIONS: Thermal insulation of all situations where high fire protection is required, insulation of ventilated facades, insulation of flat and sloping roofs under cold-applied waterproofing membranes.
SIZE: 600 x 1200 ; 1200 x 1200; 1200 x 2400 mm.
FINISH: Straight edges on all sides (shiplap edge available upon request for minimum production quantities)
THICKNESSES: 40-50-60-80-100-120 mm.
(Panel can be supplied in other dimensions and thicknesses on request)

Reaction to fire (EN 13501-1)B-s1,d0
Reaction to fire: Roofing system (External Fire Exposure) (EN 13501-5, CENT/TS 1187)Broof (t2, t3)
Compressive strenght at 10% crushing (EN 826)150 kPa
Compressive strenght at 2% crushing (EN 826)>5000 kg/ m²
Tensile strenght perpendicular to faces35 kPa
Panel density (average value, including facing weights) – ρ 45 ± 2 kg/m3
Specific heat Cp (average value)1464 J/kg °K
Vapour diffusion resistance factor (EN 12086)μ = 56 ± 2
Water absorption by partial immersion, short period (EN 1609)< 0,2 kg/ m²
Dimensional stability (EN 1604) (level)4 per d ≥ 40 mm 48 h, 70° C, 90% U
Tolerances [mm] (EN 13165)Lunghezza e Larghezza ± 5 < 1000 mm ± 7,5 da 1001 a 2000 mm
Spessore ± 2 < 50 mm, ±3 da 50 a 75 mm, +5/-2 ≥ 75 mm